Isokinetic Sampling: EPA Method 5 Step-by-Step Guide

 

Isokinetic Sampling in Stack Emission Testing: Principle, Procedure, and Importance

Isokinetic sampling is one of the most important techniques used in industrial stack emission testing. It is commonly applied to determine particulate matter (PM) emissions from industrial exhaust gases.

Industries such as cement plants, refineries, power plants, steel factories, and petrochemical facilities use particulate sampling to evaluate their emission performance and environmental compliance.

But what exactly is isokinetic sampling, why is it important, and how is it performed?

Let's understand the complete concept step by step.

1. What Is Isokinetic Sampling?

Isokinetic sampling is a technique in which the velocity of gas entering the sampling nozzle is maintained equal to the velocity of the gas flowing in the stack at the sampling point.

In simple words, the gas must enter the sampling nozzle at approximately the same speed at which it is moving inside the stack.

This condition is important because particulate matter particles have mass and momentum. If the sampling velocity is too high or too low, the collected sample may not accurately represent the actual particulate concentration in the stack.

2. Why Is Isokinetic Sampling Required?

The main purpose of isokinetic sampling is to collect a representative particulate matter sample.

There are three important sampling conditions:

A. Isokinetic Sampling

When nozzle velocity equals stack gas velocity, particulate matter enters the nozzle under representative sampling conditions.

B. Anisokinetic Sampling

When nozzle velocity is higher than stack gas velocity, the sampling is called super-isokinetic. It may result in under-sampling of larger particles.

C. Sub-Isokinetic Sampling

When nozzle velocity is lower than stack gas velocity, the sampling is called sub-isokinetic. It may result in over-sampling of larger particles.

Maintaining the correct sampling condition is essential for reliable particulate matter measurements.

3. Which EPA Method Is Used for Isokinetic Sampling?

US EPA Method 5 is a commonly used reference method for determining particulate matter emissions from stationary sources.

The method uses an isokinetic sampling train consisting of several components.

Depending on the applicable method and configuration, the equipment includes:

  • Sampling nozzle
  • Probe liner
  • Pitot tube
  • Differential pressure manometer
  • Temperature sensors
  • Heated filter holder
  • Filter assembly
  • Impingers
  • Ice bath
  • Dry Gas Meter (DGM)
  • Vacuum pump
  • Orifice meter

Each component performs a specific function during sample collection.

4. Step-by-Step Isokinetic Sampling Procedure

Step 1: Review Stack Information

Before starting the test, collect the following information:

  • Stack diameter
  • Stack temperature
  • Stack gas velocity
  • Stack pressure
  • Moisture content
  • Oxygen concentration
  • Sampling port dimensions

This information helps determine the sampling requirements.

Step 2: Perform a Preliminary Test

A preliminary velocity traverse is conducted to determine the gas velocity distribution across the stack.

The purpose is to collect the necessary information for selecting an appropriate sampling nozzle and establishing the sampling conditions.

A calibrated Type S Pitot tube is commonly used for velocity measurements.

Step 3: Select the Sampling Nozzle

The sampling nozzle is selected based on the expected stack gas velocity and the desired sampling flow rate.

The objective is to maintain the required isokinetic sampling rate throughout the test.

An incorrect nozzle size may make it difficult to maintain the required sampling conditions.

Step 4: Assemble the Sampling Train

Assemble the sampling train according to the applicable reference method.

Check the nozzle, probe, filter holder, impingers, dry gas meter, orifice meter, and vacuum system.

Verify that all connections are secure.

Step 5: Conduct Leak Checks

Perform the required pre-test leak checks according to the applicable method.

Leak checks help identify unwanted air entering the sampling system or sample gas escaping from the equipment.

Step 6: Set Sampling Conditions

Adjust the sampling flow rate to achieve the target isokinetic condition.

The sampling rate is controlled using the vacuum system and monitored through the appropriate measurement instruments.

Step 7: Collect the Sample

Insert the probe into the stack and collect the sample at each designated traverse point.

Maintain the required sampling duration and record relevant field measurements.

Important measurements include:

  • Stack gas temperature
  • Sampling gas temperature
  • Pitot differential pressure
  • Orifice pressure differential
  • Dry gas meter readings
  • Sampling time

Step 8: Complete Sample Recovery

After sampling, carefully recover the particulate matter collected on the filter and in the applicable sampling components according to Method 5.

The filter and recovered sample are handled using the prescribed recovery and laboratory procedures.

Step 9: Laboratory Analysis

The collected particulate matter is processed and weighed according to the applicable method requirements.

The final particulate matter concentration is calculated using the required sample volume and correction procedures.

Step 10: Calculate Isokinetic Percentage

The isokinetic percentage is calculated to evaluate whether the sampling was conducted under acceptable isokinetic conditions.

The applicable Method 5 acceptance criteria must be checked before reporting the results.

5. Isokinetic Sampling Formula

The general isokinetic percentage relationship is:

Isokinetic Percentage = (Sampling Nozzle Velocity / Stack Gas Velocity) × 100

For example:

Assume:

Stack gas velocity = 15 m/s

Sampling nozzle velocity = 14.7 m/s

Isokinetic Percentage:

= (14.7 / 15) × 100

= 98%

This indicates that the sampling nozzle velocity was 98% of the stack gas velocity.

The actual acceptance criteria must be verified against the applicable reference method and regulatory requirements.

6. What Happens If Isokinetic Sampling Is Not Maintained?

Incorrect sampling conditions can affect particulate matter measurement accuracy.

Possible consequences include:

  • Unrepresentative particulate matter collection.
  • Overestimation or underestimation of particulate emissions.
  • Incorrect emission calculations.
  • Unreliable compliance assessments.
  • The need for repeat testing.

Therefore, proper nozzle selection, velocity measurements, and sampling rate control are essential.

7. Common Mistakes During Isokinetic Sampling

Some common mistakes include:

  1. Selecting an incorrect nozzle diameter.
  2. Incorrectly measuring Pitot differential pressure.
  3. Not maintaining the required sampling rate.
  4. Ignoring stack temperature changes.
  5. Incorrect traverse point selection.
  6. Failing to conduct proper leak checks.
  7. Incorrect sample recovery.
  8. Recording incorrect dry gas meter readings.

Proper training and compliance with the applicable reference method help prevent these problems.

8. Conclusion

Isokinetic sampling is a critical part of particulate matter measurement in industrial stack emission testing.

Maintaining the correct relationship between nozzle velocity and stack gas velocity helps obtain representative particulate samples.

Understanding nozzle selection, preliminary velocity measurements, sampling train operation, sample recovery, and final calculations is essential for environmental engineers and stack testing professionals.

Accurate isokinetic sampling supports reliable emission measurements and effective environmental compliance monitoring.

Frequently Asked Questions

Q1. What is the purpose of isokinetic sampling?

To collect a representative particulate matter sample by maintaining the sampling nozzle velocity equal to the local stack gas velocity.

Q2. Which EPA method is commonly used for particulate matter sampling?

US EPA Method 5.

Q3. What instrument is used to measure stack gas velocity?

A calibrated Type S Pitot tube with a differential pressure measurement system.

Q4. Why is nozzle selection important?

The correct nozzle size helps achieve the required sampling velocity and flow rate.

Q5. What is super-isokinetic sampling?

It occurs when the sampling nozzle velocity is higher than the local stack gas velocity.

Q6. What is sub-isokinetic sampling?

It occurs when the sampling nozzle velocity is lower than the local stack gas velocity.

Q7. Can incorrect isokinetic sampling affect PM results?

Yes. It can cause particulate matter sampling bias and affect the accuracy of emission measurements.


About the Author

This educational article is intended for environmental engineers, QSTI candidates, stack emission testing technicians, and industrial environmental professionals.

Reference: US EPA Method 5 – Determination of Particulate Matter Emissions from Stationary Sources.

Always consult the applicable approved method revision and regulatory requirements before conducting actual stack testing.