EPA Method 1: Stack Sampling Points Explained

EPA Method 1: How to Select Stack Sampling Points and Calculate Traverse Points

Accurate stack emission testing starts with selecting the correct sampling location. Before measuring particulate matter, gas velocity, or other emission parameters, environmental professionals must determine where measurements should be taken inside the stack.

US EPA Method 1 provides procedures for selecting sampling and velocity measurement sites and determining the number and location of traverse points.

In this article, we will explain EPA Method 1, its importance, sampling location requirements, equal-area method, traverse point calculations, and common mistakes.

1. What Is US EPA Method 1?

US EPA Method 1 is a reference method used to determine suitable sampling locations and traverse points for conducting emission measurements in stationary sources.

The method helps ensure that measurements are representative of the gas flow and pollutant distribution across the stack cross-section.

It is particularly important for particulate matter testing under EPA Method 5 and velocity measurements under EPA Method 2.

2. Why Is EPA Method 1 Required?

EPA Method 1 is important for several reasons:

  • To identify suitable stack sampling locations.
  • To determine the required number of traverse points.
  • To establish the correct positions of sampling points.
  • To minimize the influence of flow disturbances.
  • To improve the representativeness of stack measurements.
  • To support accurate emission testing and calculations.

  • Incorrect sampling locations can lead to unreliable test results.

3. Requirements for Selecting a Sampling Location

A suitable sampling location should generally be selected in a straight section of the stack or duct.

EPA Method 1 provides location criteria based on distances from flow disturbances.

The commonly used criteria are:

Preferred location:

  • At least 8 stack or duct diameters downstream from a disturbance.
  • At least 2 diameters upstream from a disturbance.

Alternative location:

  • At least 2 diameters downstream.
  • At least 0.5 diameter upstream.

These are general Method 1 criteria; applicability and exceptions must be checked against the current method.

Flow disturbances may include:

  • Bends and elbows.
  • Fans.
  • Dampers.
  • Sudden expansions.
  • Sudden contractions.
  • Other changes in duct geometry.

4. What Are Traverse Points?

Traverse points are specific positions inside the stack where measurements are performed.

Since gas velocity and particulate concentration may vary across the stack, measurements at only one point may not represent the entire cross-section.

Method 1 uses an equal-area approach to distribute measurement points across the sampling plane.

5. Number of Traverse Points

The number of traverse points depends on the stack geometry and dimensions.

For circular stacks, Method 1 provides a procedure for selecting the number of points along two perpendicular diameter lines.

A commonly used minimum is 12 traverse points for a circular stack when the applicable criteria require that arrangement.

The exact number must be determined using the method's applicable criteria and stack dimensions.

6. How to Calculate Traverse Points in a Circular Stack

Let's understand the equal-area concept using an example.

Assume:

  • Stack internal diameter = 2.0 meters.
  • Number of sampling points = 12.
  • Two sampling ports located on perpendicular diameter lines.

The cross-sectional area is divided into equal-area regions, and measurement points are located at prescribed positions along the two diameter lines.

For a circular stack with 12 points, there are typically six points along each of the two perpendicular diameters.

The point locations are determined using the prescribed Method 1 equal-area calculation procedure.

7. Equal-Area Traverse Point Principle

The equal-area principle divides the stack cross-section into regions of equal area so that each measurement point represents an equal portion of the cross-section.

This helps provide a systematic distribution of measurement locations.

For example, points are not simply placed at equal linear distances from the stack wall. Their positions are calculated according to the equal-area requirements.

This distinction is important when conducting stack velocity traverses and particulate sampling.

8. Sampling Port Requirements

Sampling ports provide access for inserting the Pitot tube and sampling probe into the stack.

Important considerations include:

  1. Suitable port diameter.
  2. Safe access platform.
  3. Adequate probe insertion length.
  4. Correct port orientation.
  5. Sufficient clearance for traverse measurements.
  6. Safe working conditions.

For many circular stacks, two ports positioned at 90 degrees to each other are used when required by the method.

9. Relationship Between EPA Method 1 and Other Methods

EPA Method 1 is commonly used alongside other reference methods.

EPA MethodApplication
Method 1Sampling location and traverse points
Method 2Stack gas velocity and flow rate
Method 3AO₂ and CO₂ measurement
Method 4Moisture determination
Method 5Particulate matter sampling
Method 6CSO₂ measurement
Method 7ENOx measurement
Method 10CO measurement

Method 1 establishes the sampling locations, while the other methods provide procedures for measuring specific emission parameters.

10. Common Mistakes During Method 1

Environmental testing professionals should avoid the following mistakes:

  1. Selecting a sampling location too close to a disturbance.
  2. Measuring the stack diameter incorrectly.
  3. Ignoring stack geometry.
  4. Using incorrect traverse point locations.
  5. Failing to consider the required sampling ports.
  6. Not checking the applicable Method 1 criteria.
  7. Ignoring flow conditions that may affect measurement representativeness.

Proper planning before field testing helps avoid these problems.

11. Conclusion

US EPA Method 1 is a fundamental reference method for stationary source emission testing.

It establishes how sampling locations and traverse points should be selected to obtain representative measurements.

Understanding stack geometry, sampling location requirements, equal-area distribution, and traverse point calculations is essential for environmental engineers, stack testing technicians, and QSTI candidates.

Accurate sampling location selection is the foundation of reliable stack emission testing.

Frequently Asked Questions

Q1. What is the purpose of EPA Method 1?

It determines suitable sampling locations and traverse points for stationary source emission measurements.

Q2. What is a traverse point?

A specific location inside a stack where velocity or pollutant measurements are taken.

Q3. What is the equal-area method?

A procedure that divides the stack cross-section into equal-area regions to determine representative measurement locations.

Q4. How many traverse points are required in a circular stack?

The number depends on stack dimensions and applicable Method 1 criteria. Twelve points are commonly used in qualifying circular stacks.

Q5. Why are two sampling ports used?

Two ports positioned at approximately 90 degrees allow measurements along two perpendicular diameter lines.

Q6. Which EPA method is used after Method 1 for velocity measurements?

EPA Method 2.

Q7. Is Method 1 important for Method 5?

Yes. Method 1 helps establish the sampling location and traverse points used during particulate matter testing.


Reference: US EPA 40 CFR Part 60, Appendix A-1, Method 1 – Sample and Velocity Traverses for Stationary Sources.

Disclaimer: Always verify the current approved method, applicable exceptions, and regulatory requirements before performing actual stack testing.