EPA Method 2: How to Measure Stack Gas Velocity and Calculate Volumetric Flow Rate
Measuring stack gas velocity is an essential part of industrial stack emission testing. Before calculating the mass emission rate of pollutants, environmental professionals need to determine how fast exhaust gases are moving through the stack.
US EPA Method 2 provides procedures for determining the average gas velocity and volumetric flow rate of gas in stationary source stacks and ducts.
In this article, we will explain EPA Method 2, Type S Pitot tubes, differential pressure measurements, velocity calculations, and a practical numerical example.
1. What Is US EPA Method 2?
US EPA Method 2 is used to determine the average velocity and volumetric flow rate of exhaust gases from stationary sources.
The method commonly uses a calibrated Type S (Stauscheibe) Pitot tube to measure the differential pressure between the two sides of the Pitot tube.
The measured pressure difference is used to calculate the stack gas velocity.
2. Why Is EPA Method 2 Required?
EPA Method 2 is important because it helps environmental professionals:
- Determine average stack gas velocity.
- Calculate volumetric gas flow rate.
- Support particulate matter emission calculations.
- Calculate pollutant mass emission rates.
- Evaluate industrial exhaust flow conditions.
- Support environmental compliance testing.
Without accurate velocity and flow measurements, emission rate calculations may be unreliable.
3. Equipment Required for EPA Method 2
The following equipment is commonly used:
1. Type S Pitot Tube
Measures the differential pressure associated with stack gas velocity.
2. Differential Pressure Manometer
Measures the pressure difference between the two Pitot tube pressure connections.
3. Temperature Sensor
Measures stack gas temperature.
4. Barometer
Measures atmospheric pressure.
5. Pressure Measurement Device
Measures stack static pressure where required.
6. Sampling Probe or Suitable Probe Assembly
Provides access to the required traverse locations.
7. Gas Composition Analyzer
Provides gas composition information needed to determine molecular weight when applicable.
4. What Is a Type S Pitot Tube?
A Type S Pitot tube is a commonly used instrument for measuring gas velocity inside industrial stacks.
It has two pressure openings:
One opening faces the direction of gas flow and measures the impact or high-pressure side.
The opposite opening measures the static or low-pressure side.
The pressure difference is used to determine velocity pressure.
A properly calibrated Pitot tube is important for reliable measurements.
5. Step-by-Step EPA Method 2 Procedure
Step 1: Review Stack Information
Before testing, obtain:
- Stack diameter.
- Stack height.
- Stack temperature.
- Stack pressure.
- Stack gas composition.
- Sampling port locations.
- Number of traverse points.
Step 2: Determine Traverse Points
Use EPA Method 1 to determine the appropriate traverse locations.
The Pitot tube measurements should be taken at the prescribed points across the stack cross-section.
Step 3: Inspect and Calibrate the Pitot Tube
Inspect the Type S Pitot tube for damage, blockage, and alignment issues.
Verify the applicable calibration coefficient.
Step 4: Insert the Pitot Tube
Insert the Pitot tube into the stack through the sampling port.
Position the probe at the first designated traverse point.
The Pitot tube openings must be correctly aligned with the gas flow.
Step 5: Measure Differential Pressure
Connect the Pitot tube to a differential pressure manometer.
Record the differential pressure at each traverse point.
Step 6: Measure Stack Temperature
Measure and record the stack gas temperature at the required traverse locations.
Step 7: Determine Stack Gas Molecular Weight
Determine the dry molecular weight using the applicable gas composition measurements.
Correct for moisture when calculating the wet molecular weight.
Step 8: Calculate Stack Gas Velocity
Use the applicable Method 2 velocity equation with the measured differential pressure, gas density, and Pitot tube calibration coefficient.
Step 9: Calculate Average Gas Velocity
Calculate the average velocity using the prescribed traverse point measurements.
Step 10: Calculate Volumetric Flow Rate
Multiply the average gas velocity by the internal cross-sectional area of the stack.
The result is the volumetric flow rate at the measured conditions.
6. EPA Method 2 Stack Gas Velocity Formula
The general velocity relationship is:
V = Kp × Cp × √(ΔP × Ts / (Ps × Ms))
Where:
- V = Stack gas velocity (m/s)
- Kp = Unit conversion constant
- Cp = Pitot tube coefficient
- ΔP = Velocity pressure (Pa)
- Ts = Absolute stack gas temperature (K)
- Ps = Absolute stack gas pressure (kPa)
- Ms = Wet molecular weight of stack gas (kg/kmol)
Important: Use a consistent unit system and the appropriate Method 2 equation and conversion constant. The equation above is a general SI representation.
7. Practical Numerical Example
Assume the following measurements:
- Pitot tube coefficient = 0.84
- Differential pressure = 25 Pa
- Stack temperature = 150°C
- Absolute stack pressure = 100 kPa
- Wet molecular weight = 29 kg/kmol
First, convert the temperature:
Ts = 150 + 273.15
Ts = 423.15 K
Using the appropriate SI velocity equation and conversion constant, the calculated velocity is approximately:
V = 14.3 m/s
This is an illustrative calculation. Actual field calculations must use the measured data, correct units, calibration coefficient, and the applicable reference method.
8. How to Calculate Stack Volumetric Flow Rate
The general equation is:
Q = V × A
Where:
- Q = Volumetric flow rate (m³/s)
- V = Average stack gas velocity (m/s)
- A = Internal stack cross-sectional area (m²)
Assume:
Stack diameter = 2.0 m
Average gas velocity = 14.3 m/s
First calculate the stack area:
A = π × D² / 4
A = 3.1416 × 2² / 4
A = 3.1416 m²
Now calculate the flow rate:
Q = 14.3 × 3.1416
Q = 44.93 m³/s
This is the volumetric flow rate at the measured stack conditions.
9. Difference Between Actual and Standard Volumetric Flow Rate
Actual volumetric flow rate represents the gas volume at the measured operating conditions.
Standard volumetric flow rate represents the gas volume corrected to specified standard temperature and pressure conditions.
The conversion depends on the selected standard conditions and whether moisture correction is required.
For an ideal gas:
Qstandard = Qactual × (Pactual / Pstandard) × (Tstandard / Tactual)
Pressure and temperature must be absolute.
10. Common Mistakes During EPA Method 2
- Using an incorrect Pitot tube coefficient.
- Incorrectly connecting the manometer.
- Taking measurements at incorrect traverse points.
- Ignoring stack temperature.
- Using incorrect molecular weight.
- Incorrect pressure unit conversions.
- Failing to align the Pitot tube with gas flow.
- Using gauge pressure instead of absolute pressure where absolute pressure is required.
11. Relationship Between EPA Method 1 and Method 2
EPA Method 1 determines the appropriate sampling and velocity traverse points.
EPA Method 2 uses those points to measure differential pressure and calculate stack gas velocity and volumetric flow rate.
Both methods are essential for obtaining representative stack flow measurements.
12. Conclusion
US EPA Method 2 is a fundamental reference method for determining stack gas velocity and volumetric flow rate.
Understanding Type S Pitot tubes, differential pressure measurements, stack temperature, gas molecular weight, and flow calculations is essential for reliable industrial emission testing.
Accurate velocity and flow measurements also support the calculation of pollutant mass emission rates and environmental compliance assessments.
Frequently Asked Questions
Q1. Which instrument is used in EPA Method 2?
A calibrated Type S Pitot tube and differential pressure manometer are commonly used.
Q2. What does a Pitot tube measure?
It measures the pressure difference associated with gas velocity.
Q3. What is velocity pressure?
It is the pressure difference used to calculate gas velocity.
Q4. Which method determines traverse points?
US EPA Method 1.
Q5. What is volumetric flow rate?
It is the volume of gas passing through a cross-section per unit time.
Q6. What is the difference between actual and standard flow rate?
Actual flow rate is measured at operating conditions, while standard flow rate is corrected to specified reference conditions.
Q7. Why is molecular weight required?
Gas molecular weight is needed to determine gas density, which is used in the velocity calculation.
Reference: US EPA Method 2 – Determination of Stack Gas Velocity and Volumetric Flow Rate (Type S Pitot Tube).
Disclaimer: This article is for educational purposes. Always consult the applicable approved EPA method and regulatory requirements when conducting actual emission measurements.